Laser Doppler Velocimeter:
TSI two channel LDV for high
spatial and temporal resolution measurements of water velocity. The LDV is capable of measuring
downstream and vertical velocities with data rates in the kHz range. The sample volume is
less than 1 mm3.
Manufactured by TSI Inc.
Back To Top
|
|
Sontek Acoustic Doppler Velocimeter (ADV):
The ADV can be used in real time mode in the LUMCON Flume
or can be deployed independently at a field site. It is capable of 3-D velocity
measurements at rates up to 50 Hz. The sample volume is approximately 1 cm3
Manufactured by Sontek .
Back To Top
|
 |
Ocean Optics Fiber Optic Oxygen Meter:
Oxygen concentration in measured at the tip of a 300 micron optical fiber. The fiber is
coated in a dye that fluoresces in blue light. Fluorescence is quenched in the presence
of oxygen. Thus the oxygen concentration is inversely proportional to the amount of fluorescence.
Manufactured by Ocean Optics
-(Model SF2000)
Back To Top
|
 |
PME Micro-conductivity/Temperature Meter:
Conductivity is measured at the tip of this glass needle probe. The sensor, which is 500
microns in width, consists of four platinum electrodes.
Manufactured by PME
-(Model 125)
Back To Top
|
|
|
LiCor Quantum/Radiometer/Photometer:
This system is used to measure photosynthetically active radiation (PAR).
An underwater housing is available for use in wet and submerged environments.
Manufactured by LiCor
-(Model LI-250)
Back To Top
|
 |
Diving PAM Underwater Fluorometer:
Pulse Amplitude Modulation Fluorometry is a relatively new technique for measuring
photosynthesis rates of plants or corals in their natural environment. The PAM technique
takes advantage of chlorophyll fluorescence.
Manufactured by WALZ.
Back To Top
|
 |
Campbell CR10X Data Loggers :
Eureka Environmental Manta Water Quality Probe :
The Manta Water Quality Probe from Eureka Environmental is used to collect data along Bayou Terrebonne and Bayou Little Caillou. We use the Manta to collect temperature, conductivity, salinity, pH, dissolved oxygen (mg/L and percent saturation), and depth. We are currently interested in hypoxia along Bayou Terrebonne and how developed areas affect dissolved oxygen concentrations. The Finelli Lab uses five individual Manta units.
Back To Top
|
 |
Nortek Aquadopp Current Profiler:
The Aquadopp Current Profiler manufactured by Nortek AS is a handy tool used to measure the speed and movement direction of a column of water. This unit is also known as an ADCP, or Acoustic Doppler Current Profiler.
Back To Top
|
 |
|